ARC Wireless FreeStation 5
ARC Wireless FreeStation 5
Type: CPE, access point
Power: 24 VDC, 0.7 A
Connector type: Ethernet (PoE)
PoE tag: non-standard
CPU1: Ralink RT3050 (320 MHz)
FLA1: 8 MiB8,388,608 B <br />65,536 Kib <br />8,192 KiB <br />64 Mib <br />0.00781 GiB <br /> (Macronix MX29LV640ETTI-70G)
RAM1: 32 MiB33,554,432 B <br />262,144 Kib <br />32,768 KiB <br />256 Mib <br />0.0313 GiB <br /> (Winbond W9825G6JH-61)
Expansion IFs: USB 2.0
USB ports: 2
Serial: yes, 3.3V TTL
WI1 module: 8devices Carambola
WI1 module IF: SIP (on-board)
WI1 chip1: Ralink RT3050
WI1 802dot11 protocols: bgn
WI1 MIMO config: 1x1:1
WI1 antenna connector: U.FL
WI2 module: ARCFlex AFM2
WI2 module IF: USB (non-standard connector)
WI2 chip1: Ralink RT3572
WI2 802dot11 protocols: an
WI2 MIMO config: 2x2:2
WI2 antenna connector: U.FL
ETH chip1: Ralink RT3050
LAN speed: 100M
LAN ports: 2
abgn
Additional chips
USB 2.0 High Speed 4-Port Hub Controller;Terminus;FE1.1;LG3S945A6410;;1;
Stock bootloader: U-Boot 1.1.3 Ralink v3.3
Stock FW OS: Linux 2.6.21.7
Default SSID: arcweb
Default IP address: 192.168.10.1
the IP 192.168.10.1 is used by 123 additional devices
of which 0 are ARC Wireless devices
Default login user: admin
Default login password: admin
admin:admin credentials used by 1327 additional devices
of which 0 are ARC Wireless devices
FCC ID | |
---|---|
8devices Carambola | Z9W-CM1 |
For a list of all currently documented Ralink chipsets with specifications, see Ralink.
ARCFlex 5GHz 300Mbps MIMO CPE
The FCC IDs for this device are likely Z2B-AFM1 (RT3050 board)
- and Z2B-AFM2 (RT3572 module).
- Dual Radio - 2.4GHz AP (21dBi), 5GHz MIMO CPE (25dBi) w/ 18dBi antenna
- 802.11bgn (150Mbps), 802.11an (300Mbps), all outdoor enclosure
- POE Passthrough up to 24V, polarity independent
The same hardware is likely used for the FreeStation 2.
- MX29LV640ETTI-70G Flash in the RT3050 board filing.
- Assumed A8:87:ED OUI...
Per ARC Wireless' wiki...
- the default SSID is arcweb (for both radios?)
- the default IP is apparently 10.100.100.49 if connected via the installer network
- or 192.168.10.1 if connected via private wireless or by Ethernet
- the default password for the UI and telnet are admin/admin and user/user
- PoE input port is eth0, output is eth1 (but PoE passthrough is disabled by default)