Broadcom BCM6348S

From WikiDevi.Wi-Cat.RU
(Redirected from Broadcom BCM6348)
Jump to navigation Jump to search

Information

BCM6348

BCM6348B0

  • System-On-Chip: Broadcom 6348 (CPU type 0x29107)
  • CPU Speed: 240MHz, Bus: 133MHz, Ref: 26MHz

BCM6348S

  • System-On-Chip: Broadcom 6348 (CPU type 0x29107)
  • CPU Speed: 240MHz, Bus: 133MHz, Ref: 26MHz
See also: BMIPS3300

JTAG

  • K17 JTAG_SEL in JTAG Selection
  • L17 JTAG_TDO out JTAG Test Data Output
  • L18 JTAG_TDI in JTAG Test Data Input
  • L19 JTAG_TMS in JTAG Test Mode Select
  • L20 JTAG_TCK in JTAG Test Clock
  • M18 JTAG_TRST_B in JTAG Test Reset

UART

  • K18 UART_SOUT out UART Serial Output
  • K19 UART_SIN in UART Serial Input

Wikis

Broadcom BCM6348SKFBG - MIPS (BMIPS3300 V0.7) @256MHz
CFE version 1.0.37-6.5.17 for BCM96348 (32bit,SP,BE)
CPU type 0x29107: 256MHz, Bus: 128MHz, Ref: 32MHz
An upgraded version of the BCM6345 with ADSL2+ support,
support for a separate VoIP DSP.
It is mostly combined with the BCM6301 line driver,
but can also be combined with a BCM6505 VDSL transceiver.

Broadcom BCM6348SKFBG pinout

Broadcom BCM6348SKPBG - BGA package (400-ball 21x21mm)
 • Pinout
=============================
Broadcom BCM6348SKFBG pinout
400-ball 21x21mm BGA package
=============================

A1	MPI_RST_B
A2	MPI_BOOT_B/EBI_CS_B0		out	EBI Chip Select 0
A3	DVDDO1				linkage	Digital Supply Voltage
A4	EPHY_RDAC
A5	EPHY_TDN
A6	EPHY_RDN
A7	PNP_3P3_CTRL			linkage	Control Supply Voltage 3.3V
A8	PNP_3P3_SENSE			linkage	Sense Supply Voltage 3.3V
A9	EPHY_LNK_ACT_LED_B		out	EPHY Link/Activity LED
A10	SD_DQ13				inout	SDRAM Data 13
A11	DVDDO2				linkage	Digital Supply Voltage
A12	SD_DQ5				inout	SDRAM Data 5
A13	SD_DQ7				inout	SDRAM Data 7
A14	SD_DQM0				out	SDRAM Data Byte Mask 0
A15	SD_RAS_B			out	SDRAM Row Address Strobe
A16	DVDDO3				linkage	Digital Supply Voltage
A17	SD_A11				out	SDRAM Address 11
A18	SD_BSA1				out	SDRAM Bank Select Address 1
A19	SD_A0				out	SDRAM Address 0
A20	SD_DQM3				out	SDRAM Data Byte Mask 3

B1	MPI_AD22			out	EBI Address 4
B2	MPI_CS_B1/EBI_CS_B1		out	EBI Chip Select 1
B3	DGND1				linkage	Digital Ground
B4	EPHY_VREF
B5	EPHY_TDP
B6	EPHY_RDP
B7	PNP_2P5_SENSE
B8	EPHY_SPD_LED_B			out	EPHY Speed LED
B9	SD_DQ15				inout	SDRAM Data 15
B10	SD_DQ3				inout	SDRAM Data 3
B11	DGND2				linkage	Digital Ground
B12	SD_DQ11				inout	SDRAM Data 11
B13	SD_DQ9				inout	SDRAM Data 9
B14	SD_CAS_B			out	SDRAM Column Address Strobe
B15	SD_CS_B				out	SDRAM Chip Select
B16	DGND3				linkage	Digital Ground
B17	SD_A8				out	SDRAM Address 8
B18	SD_A6				out	SDRAM Address 6
B19	SD_A5				out	SDRAM Address 5
B20	SD_DQ16				inout	SDRAM Data 16

C1	MPI_AD25			out	EBI Address 1
C2	GPIO17/PCI_REQ0_B		inout	GPIO 17
C3	MPI_WE_B
C4	GPIO18/PCI_REQ1_B		inout	GPIO 18
C5	PNP_2P5_CTRL
C6	EPHY_PLL_VDD			linkage	EPHY PLL Supply Voltage
C7	DGND4				linkage	Digital Ground
C8	USB1_LED_B			out	USB Port 1 LED
C9	SD_DQ1				inout	SDRAM Data 1
C10	SD_DQ2				inout	SDRAM Data 2
C11	SD_DQ4				inout	SDRAM Data 4
C12	SD_DQ10				inout	SDRAM Data 10
C13	SD_DQ8				inout	SDRAM Data 8
C14	SD_DQM1				out	SDRAM Data Byte Mask 1
C15	SD_CKE				out	SDRAM Clock Enable
C16	SD_BSA0				out	SDRAM Bank Select Address 0
C17	SD_A7				out	SDRAM Address 7
C18	SD_A1				out	SDRAM Address 1
C19	SD_A4				out	SDRAM Address 4
C20	SD_DQ30				inout	SDRAM Data 30

D1	MPI_AD18
D2	MPI_AD31			inout	EBI Data 10
D3	MPI_AD28			inout	EBI Data 8
D4	GPIO20/PCI_GNT1_B		inout	GPIO 20
D5	EPHY_PLL_GND			linkage	EPHY PLL Ground
D6	DGND5				linkage	Digital Ground
D7	EPHY_BIAS_VDD
D8	PNP_2P5_SUPPLY
D9	SD_DQ0				inout	SDRAM Data 0
D10	SD_DQ14				inout	SDRAM Data 14
D11	DVDDO4				linkage	Digital Supply Voltage
D12	SD_DQ6				inout	SDRAM Data 6
D13	SD_WE_B				out	SDRAM Write Enable
D14	SD_CLK				out	SDRAM Clock
D15	SD_A9				out	SDRAM Address 9
D16	SD_A10				out	SDRAM Address 10
D17	SD_A2				out	SDRAM Address 2
D18	SD_DQM2				out	SDRAM Data Byte Mask 2
D19	SD_A12				out	SDRAM Address 12
D20	SD_DQ29				inout	SDRAM Data 29

E1	DVDDO5				linkage	Digital Supply Voltage
E2	DGND6				linkage	Digital Ground
E3	MPI_AD26			out	EBI Address 0
E4	GPIO19/PCI_GNT0_B		inout	GPIO 19
E5	DGND7				linkage	Digital Ground
E6	DGND8				linkage	Digital Ground
E7	PNP_3P3_SUPPLY
E8	RESERVED-E8			linkage
E9	DGND9				linkage	Digital Ground
E10	DGND10				linkage	Digital Ground
E11	SD_DQ12				inout	SDRAM Data 12
E12	RESERVED-E12			linkage
E13	RESERVED-E13			linkage
E14	DVDDO6				linkage	Digital Supply Voltage
E15	DVDDO7				linkage	Digital Supply Voltage
E16	DGND11				linkage	Digital Ground
E17	SD_DQ18				inout	SDRAM Data 18
E18	SD_DQ31				inout	SDRAM Data 31
E19	DGND12				linkage	Digital Ground
E20	DVDDO8				linkage	Digital Supply Voltage

F1	MPI_FRAME_B/PCI_FRAME_B
F2	MPI_AD19			out	EBI Address 7
F3	MPI_CLK/PCI_CLK
F4	MPI_AD24			out	EBI Address 2
F5	GPIO16/PCI_INTA_B		inout	GPIO 16
F6	MPI_CS_B3/EBI_CS_B3		out	EBI Chip Select 3
F7	EPHY_BIAS_GND
F8	RESERVED-F8			linkage
F9	RESERVED-F9			linkage
F10	DVDDP1				linkage	Digital Supply Voltage
F11	DGND13				linkage	Digital Ground
F12	RESERVED-F12			linkage
F13	RESERVED-F13			linkage
F14	DVDDP2				linkage	Digital Supply Voltage
F15	DGND14				linkage	Digital Ground
F16	RESERVED-F16			linkage
F17	SD_A3				out	SDRAM Address 3
F18	SD_DQ17				inout	SDRAM Data 17
F19	SD_DQ28				inout	SDRAM Data 28
F20	SD_DQ20				inout	SDRAM Data 20

G1	MPI_D2/EBI_D2			inout	EBI Data 2
G2	MPI_CBE_B3
G3	MPI_AD20			out	EBI Address 6
G4	MPI_AD30			inout	EBI Data 9
G5	MPI_CS_B2/EBI_CS_B2		out	EBI Chip Select 2
G6	RESERVED-G6			linkage
G7	DVDDC1				linkage	Digital Supply Voltage
G8	DVDDC2				linkage	Digital Supply Voltage
G9	DVDDC3				linkage	Digital Supply Voltage
G10	DVDDC4				linkage	Digital Supply Voltage
G11	DVDDC5				linkage	Digital Supply Voltage
G12	DVDDC6				linkage	Digital Supply Voltage
G13	DVDDC7				linkage	Digital Supply Voltage
G14	DGND15				linkage	Digital Ground
G15	DGND16				linkage	Digital Ground
G16	DVDDO9				linkage	Digital Supply Voltage
G17	SD_DQ19				inout	SDRAM Data 19
G18	SD_DQ21				inout	SDRAM Data 21
G19	SD_DQ27				inout	SDRAM Data 27
G20	SD_DQ22				inout	SDRAM Data 22

H1	MPI_AD17
H2	MPI_AD21			out	EBI Address 5
H3	MPI_AD23			out	EBI Address 3
H4	MPI_AD29/EBI_D1			inout	EBI Data 1
H5	GPIO21/PCI_IDSEL		inout	GPIO 21
H6	RESERVED-H6			linkage
H7	DVDDC8				linkage	Digital Supply Voltage
H8	DGND17				linkage	Digital Ground
H9	DVDDC9				linkage	Digital Supply Voltage
H10	DGND18				linkage	Digital Ground
H11	DGND19				linkage	Digital Ground
H12	SYS_IRQ_B
H13	USE_SPI_SLAVE			in	Use SPI slave mode
H14	DVDDC10				linkage	Digital Supply Voltage
H15	DGND20				linkage	Digital Ground
H16	DGND21				linkage	Digital Ground
H17	SD_DQ23				inout	SDRAM Data 23
H18	SD_DQ24				inout	SDRAM Data 24
H19	SD_DQ26				inout	SDRAM Data 26
H20	SYS_RESET_B

J1	MPI_PCI_DEVSEL_B
J2	MPI_TRDY_B/PCI_TRDY_B
J3	MPI_AD16/PCI_AD16
J4	MPI_AD27/EBI_D0			inout	EBI Data 0
J5	DGND22				linkage	Digital Ground
J6	DVDDO10				linkage	Digital Supply Voltage
J7	DVDDC11				linkage	Digital Supply Voltage
J8	DVDDC12				linkage	Digital Supply Voltage
J9	DGND23				linkage	Digital Ground
J10	DGND24				linkage	Digital Ground
J11	RESERVED-J11			linkage
J12	RESERVED-J12			linkage
J13	RESERVED-J13			linkage
J14	RESERVED-J14			linkage
J15	DGND25				linkage	Digital Ground
J16	DVDDO11				linkage	Digital Supply Voltage
J17	SPI_MOSI			out	SPI Master Out Slave In 
J18	SPI_MISO			in	SPI Master In Slave Out
J19	SPI_CLK				out	SPI Serial Clock
J20	SD_DQ25				inout	SDRAM Data 25

K1	DVDDO12				linkage	Digital Supply Voltage
K2	DGND26				linkage	Digital Ground
K3	MPI_STOP_B/PCI_STOP_B
K4	MPI_CBE_B2
K5	DVDDO13				linkage	Digital Supply Voltage
K6	DVDDO14				linkage	Digital Supply Voltage
K7	DGND27				linkage	Digital Ground
K8	DGND28				linkage	Digital Ground
K9	DGND29				linkage	Digital Ground
K10	DGND30				linkage	Digital Ground
K11	RESERVED-K11			linkage
K12	RESERVED-K12			linkage
K13	PWM_SYNC_CLK
K14	RESERVED-K14			linkage
K15	RESERVED-K15			linkage
K16	DVDDP3				linkage	Digital Supply Voltage
K17	JTAG_SEL			in	JTAG Selection
K18	UART_SOUT			out	UART Serial Output
K19	UART_SIN			in	UART Serial Input
K20	SPI_SS_B			out	SPI Slave Select

L1	MPI_IRDY_B
L2	MPI_PERR_B
L3	MPI_A23
L4	MPI_D14/EBI_D14			inout	EBI Data 14
L5	DGND31				linkage	Digital Ground
L6	DVDDO15				linkage	Digital Supply Voltage
L7	DVDDC13				linkage	Digital Supply Voltage
L8	DVDDC14				linkage	Digital Supply Voltage
L9	DGND32				linkage	Digital Ground
L10	DGND33				linkage	Digital Ground
L11	DGND34				linkage	Digital Ground
L12	RESERVED-L12			linkage
L13	RESERVED-L13			linkage
L14	RESERVED-L14			linkage
L15	DGND35				linkage	Digital Ground
L16	DVDDO16				linkage	Digital Supply Voltage
L17	JTAG_TDO			out	JTAG Test Data Output
L18	JTAG_TDI			in	JTAG Test Data Input
L19	JTAG_TMS			in	JTAG Test Mode Select
L20	JTAG_TCK			in	JTAG Test Clock

M1	MPI_AD15
M2	MPI_PAR
M3	MPI_CBE_B1
M4	MPI_AD11/EBI_RD_B		?	EBI RD
M5	MPI_LOCK_B/PCI_LOCK_B
M6	DVDDO17				linkage	Digital Supply Voltage
M7	DVDDC15				linkage	Digital Supply Voltage
M8	DGND36				linkage	Digital Ground
M9	DGND37				linkage	Digital Ground
M10	DGND38				linkage	Digital Ground
M11	RESERVED-M11			linkage
M12	RESERVED-M12			linkage
M13	RESERVED-M13			linkage
M14	DVDDC16				linkage	Digital Supply Voltage
M15	DGND39				linkage	Digital Ground
M16	DGND40				linkage	Digital Ground
M17	RESERVED-M17			linkage
M18	JTAG_TRST_B			in	JTAG Test Reset
M19	DGND41				linkage	Digital Ground
M20	DVDDO18				linkage	Digital Supply Voltage

N1	MPI_AD13
N2	MPI_AD12			out	EBI Address 11
N3	MPI_SERR_B
N4	MPI_AD14
N5	DGND42				linkage	Digital Ground
N6	DVDDO19				linkage	Digital Supply Voltage
N7	DVDDC17				linkage	Digital Supply Voltage
N8	DGND43				linkage	Digital Ground
N9	DGND44				linkage	Digital Ground
N10	DGND45				linkage	Digital Ground
N11	RESERVED-N11			linkage
N12	RESERVED-N12			linkage
N13	GPIO36				inout	GPIO 36
N14	DGND46				linkage	Digital Ground
N15	DVDDP4				linkage	Digital Supply Voltage
N16	DGND47				linkage	Digital Ground
N17	RESERVED-N17			linkage
N18	RESERVED-N18			linkage
N19	RESERVED-N19			linkage
N20	RESERVED-N20			linkage

P1	MPI_CBE_B3
P2	MPI_AD9				out	EBI Address 10
P3	MPI_AD8/EBI_D15			inout	EBI Data 15
P4	MPI_AD6/EBI_D13			inout	EBI Data 13
P5	DGND48				linkage	Digital Ground
P6	DVDDO20				linkage	Digital Supply Voltage
P7	DVDDC18				linkage	Digital Supply Voltage
P8	DGND49				linkage	Digital Ground
P9	DVDDC19				linkage	Digital Supply Voltage
P10	DGND50				linkage	Digital Ground
P11	RESERVED-P11			linkage
P12	RESERVED-P12			linkage
P13	RESERVED-P13			linkage
P14	DGND51				linkage	Digital Ground
P15	DGND52				linkage	Digital Ground
P16	DVDDO21				linkage	Digital Supply Voltage
P17	GPIO33/EXT_IRQ1			inout	GPIO 33
P18	GPIO34/EXT_IRQ2			inout	GPIO 34
P19	GPIO35/EXT_IRQ3			inout	GPIO 35
P20	ADSL_ACT_LED_B			out	ADSL Activity LED

R1	MPI_AD10/PCI_AD10		out	EBI Address 18
R2	MPI_AD4				inout	EBI Data 12
R3	MPI_AD5				inout	EBI Data 6
R4	MPI_AD0				inout	EBI Data 3
R5	DGND53				linkage	Digital Ground
R6	DVDDO22				linkage	Digital Supply Voltage
R7	DGND54				linkage	Digital Ground
R8	DGND55				linkage	Digital Ground
R9	DVDDC20				linkage	Digital Supply Voltage
R10	DGND56				linkage	Digital Ground
R11	DVDDC21				linkage	Digital Supply Voltage
R12	DVDDC22				linkage	Digital Supply Voltage
R13	AFE_RXMOD_AGND1			linkage	AFE Analog Ground
R14	AFE_RXMOD_AGND2			linkage	AFE Analog Ground
R15	AFE_RXMOD_AGND3			linkage	AFE Analog Ground
R16	AFE_TX_DGND1			linkage	AFE Digital Ground
R17	AFE_TX_DGND2			linkage	AFE Digital Ground
R18	AFE_TX_DVDD			linkage	AFE Digital Supply Voltage
R19	AFE_TXBUF_AVDD1			linkage	AFE Analog Supply Voltage
R20	AFE_TXBUF_AVDD2			linkage	AFE Analog Supply Voltage

T1	DVDDO23				linkage	Digital Supply Voltage
T2	DGND57				linkage	Digital Ground
T3	MPI_AD1				inout	EBI Data 4
T4	GPIO25/PCMCIA_VS1/UART_CTS	inout	GPIO 25
T5	GPIO31/UTO_TXADDR1		inout	GPIO 31
T6	GPIO30/UTO_TXADDR0		inout	GPIO 30
T7	DVDDO24				linkage	Digital Supply Voltage
T8	UTO_TXEN_B/MII_TXER
T9	UTO_RXEN_B/MII_CRS
T10	DGND58				linkage	Digital Ground
T11	DVDDP5				linkage	Digital Supply Voltage
T12	DGND59				linkage	Digital Ground
T13	AFE_RXMOD_AVDD1			linkage	AFE Analog Supply Voltage
T14	AFE_RXMOD_AVDD2			linkage	AFE Analog Supply Voltage
T15	AFE_RXMOD_AGND4			linkage	AFE Analog Ground
T16	DYING_GASP_VIN
T17	REF_TX
T18	AFE_TXBUF_AGND2			linkage	AFE Analog Ground
T19	AFE_TXN				out	AFE Negative Transmit Output
T20	AFE_TXP				out	AFE Positive Transmit Output

U1	MPI_AD7				inout	EBI Data 7
U2	MPI_AD2				inout	EBI Data 11
U3	GPIO24/PCMCIA_CD2/UART_DSR	inout	GPIO 24
U4	GPIO28/UTO_RXADDR0		inout	GPIO 28
U5	GPIO3/UTO_TXD7			inout	GPIO 3
U6	GPIO6/UTO_RXD6			inout	GPIO 6
U7	GPIO13/UTO_TXD1/MII_TXD1	inout	GPIO 13
U8	GPIO32/EXT_IRQ0			inout	GPIO 32
U9	UTO_RXCLAV/MII_RXDV
U10	USB1_PWRON				USB Port 1 Power Enable
U11	USB1_DP				inout	USB Port 1 Data Positive		
U12	USB0_DN				inout	USB Port 0 Data Negative
U13	USB1_ACTIVE				USB Port 1 Active
U14	AFE_CORE_DVDD			linkage	AFE Digital Supply Voltage
U15	AFE_RXMOD_AVDD3			linkage	AFE Analog Supply Voltage
U16	AFE_RXMOD_AVDD4			linkage	AFE Analog Supply Voltage
U17	AFE_TXDAC_AVDD1			linkage	AFE Analog Supply Voltage
U18	AFE_TXDAC_AVDD2			linkage	AFE Analog Supply Voltage
U19	AFE_TXDAC_AGND			linkage	AFE Analog Ground
U20	AFE_TXBUF_AGND1			linkage	AFE Analog Ground

V1	MPI_AD3				inout	EBI Data 5
V2	GPIO26/PCMCIA_VS2/UART_DTR	inout	GPIO 26
V3	GPIO29/UTO_RXADDR1		inout	GPIO 29
V4	GPIO2/UTO_TXD6			inout	GPIO 2
V5	GPIO7/UTO_RXD7			inout	GPIO 7
V6	GPIO8/UTO_RXD0/MII_RXD0		inout	GPIO 8
V7	GPIO12/UTO_TXD0/MII_TXD0	inout	GPIO 12
V8	UTO_TXSOC/MII_MDIO
V9	UTO_EXT_CLK/MII_TX_CLK
V10	USB1_PWRFLT			in	USB Port 1 Power Fault
V11	USB1_DN				inout	USB Port 1 Data Negative
V12	USB0_DP				inout	USB Port 0 Data Positive
V13	ADSL_PLL_GND			linkage	ADSL PLL Ground
V14	AFE_CORE_DGND			linkage	AFE Digital Ground
V15	AFE_RX_DGND1			linkage	AFE Digital Ground
V16	AFE_RXMOD_AVDD5			linkage	AFE Analog Supply Voltage
V17	AFE_RXPGA_AVDD1			linkage	AFE Analog Supply Voltage
V18	AFE_RXPGA_AVDD2			linkage	AFE Analog Supply Voltage
V19	AFE_RXPGA_AGND1			linkage	AFE Analog Ground
V20	AFE_RXPGA_AGND2			linkage	AFE Analog Ground

W1	GPIO27/UART_RTS			inout	GPIO 27
W2	GPIO22/PCMCIA_READY/UART_DCD	inout	GPIO 22
W3	GPIO0/UTO_TXD4			inout	GPIO 0
W4	GPIO4/UTO_RXD4			inout	GPIO 4
W5	DGND60				linkage	Digital Ground
W6	GPIO11/UTO_RXD3/MII_RXD3	inout	GPIO 11
W7	GPIO14/UTO_TXD2/MII_TXD2	inout	GPIO 14
W8	UTO_RXCLK/MII_RX_CLK
W9	UTO_RXSOC/MII_RXER
W10	USB0_PWRON				USB Port 0 Power Enable
W11	MIPS_PLL_VDD			linkage	MIPS PLL Supply Voltage
W12	MIPS_PLL_GND			linkage	MIPS PLL Ground
W13	SYS_PLL_GND			linkage	SYS PLL Ground
W14	XTALI				linkage	Crystal Oscillator Input
W15	AFE_RX_DGND2			linkage	AFE Digital Ground
W16	AFE_RXMOD_AVDD6			linkage	AFE Analog Supply Voltage
W17	AFE_RXMOD_AGND5			linkage	AFE Analog Ground
W18	AFE_RXMOD_AGND6			linkage	AFE Analog Ground
W19	AFE_RXPGA_AGND3			linkage	AFE Analog Ground
W20	AFE_RXP				in	AFE Positive Receive Input

Y1	GPIO23/PCMCIA_CD1/UART_RI	inout	GPIO 23
Y2	GPIO1/UTO_TXD5			inout	GPIO 1
Y3	GPIO5/UTO_RXD5			inout	GPIO 5
Y4	GPIO9/UTO_RXD1/MII_RXD1		inout	GPIO 9
Y5	DVDDO25				linkage	Digital Supply Voltage
Y6	GPIO10/UTO_RXD2/MII_RXD2	inout	GPIO 10
Y7	GPIO15/UTO_TXD3/MII_TXD3	inout	GPIO 15
Y8	UTO_TXCLK/MII_TXEN
Y9	UTO_TXCLAV/MII_COL
Y10	USB1_RDY				USB Port 1 Ready
Y11	USB0_PWRFLT			in	USB Port 0 Power Fault
Y12	ADSL_PLL_VDD			linkage	ADSL PLL Supply Voltage
Y13	SYS_PLL_VDD			linkage	SYS PLL Supply Voltage
Y14	XTALO				linkage	Crystal Oscillator Output
Y15	AFE_RX_DVDD			linkage	AFE Digital Supply Voltage
Y16	AFE_RXMOD_AVDD7			linkage	AFE Analog Supply Voltage
Y17	AFE_RXMOD_AGND7			linkage	AFE Analog Ground
Y18	REF_RX
Y19	AFE_RXPGA_AGND4			linkage	AFE Analog Ground
Y20	AFE_RXN				in	AFE Negative Receive Input

See also FCC Schematics, Block Diagram and Parts List (T&W/SGE)..

Information

  • AFE - Analog Front-End
  • EBI (External Bus Interface) is part of the MPI (Multi-Peripheral Interface)
  • EPHY - Ethernet Physical Transceiver
  • GPIO - General Purpose Input/Output
  • PLL - Phase-Locked Loop
  • USB - Universal Serial Bus
  • UART - Universal Asynchronous Receiver/Transmitter

Table of Systems

Device Type PHY modes Manuf. CPU1 FLA1 RAM1 WI1 WI2 Switch Ether. Expan. Ports FCC date
ASUS DSL-G31
FCC ID: MSQDSL-G31, QMPM505
wireless router

dsl modem

bg
SGE

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
256 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4318E
?x?:?, bg
Broadcom
BCM5325E
100M
4x LAN
2009-07-27
ASUS DSL-N13
FCC ID: MSQDSLN13
wireless router

dsl modem

bgn
ASUS
Broadcom
BCM6348S
240 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 32 MiB33,554,432 B <br />262,144 Kib <br />32,768 KiB <br />256 Mib <br />0.0313 GiB <br /> Ralink
RT2880
2x3:2, bgn
Ant. conn: U.FL

Is a module
Broadcom
BCM5325E
100M
4x LAN
Mini PCI

USB 2.0

2x USB
2008-05-02
D-Link DSL-2600B
FCC ID: KA2SL2600UT, MSQAAM6KVIB6
wireless router

dsl modem

bg
ASUS
Broadcom
BCM6348S
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4318
?x?:?, bg
Ant. conn: U.FL
Broadcom
BCM5325E
100M
4x LAN
2007-04-02
D-Link DSL-2640B rev B2 wireless router

dsl modem

bg

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4318
?x?:?, bg
Ant. conn: U.FL, RP-SMA
Broadcom
BCM5325E
100M
4x LAN
DQ Technology VisionNet M505
FCC ID: QMPM505
wireless router

dsl modem

bg
SGE

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
256 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4318E
?x?:?, bg
Broadcom
BCM5325E
100M
4x LAN
USB 2.0 1x USB
2007-03-13
Netgear DG834Gv4
FCC ID: PY307200068
has internal images
wireless router

dsl modem

bg
SerComm

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4318
?x?:?, bg
Broadcom
BCM5325E
100M
4x LAN
2007-07-17
Netgear DGN2000
FCC ID: PY308100081
wireless router

dsl modem

bgn
SerComm
Broadcom
BCM6348S
Broadcom
BCM4322
2x2:2, bgn
Broadcom
BCM5325E
100M
4x LAN
2008-06-02
Sagemcom F@ST 2504 wireless router

dsl modem

bg
Broadcom
BCM6348S
240 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 64 MiB67,108,864 B <br />524,288 Kib <br />65,536 KiB <br />512 Mib <br />0.0625 GiB <br /> Broadcom
BCM4318
?x?:?, bg
Broadcom
BCM5325E
100M
4x LAN
SerComm IP1006GA/GB
FCC ID: P27IP1006GA
wireless router

dsl modem

bgn
SerComm

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4322
2x2:2, bgn
Ant. conn: RP-SMA
Broadcom
BCM5325
100M
4x LAN
2008-11-18
TP-LINK TD-W8900G
FCC ID: TE7TDW8900G
wireless router

dsl modem

bg
TP-LINK

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
256 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Atheros
AR2414A
?x?:?, bg
Ant. conn: RP-SMA
Marvell
88E6060
100M
4x LAN
2008-01-09
TP-LINK TD-W8910G v1.x
FCC ID: TE7TDW8910G, TE7WN55XG
wireless router

dsl modem

bg
TP-LINK

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
256 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Atheros
AR2413A
?x?:?, bg
Ant. conn: U.FL

Is a module
Marvell
88E6060
100M
4x LAN
Mini PCI 2007-08-31
TP-LINK TD-W8920G
FCC ID: TE7TDW8920G
wireless router

dsl modem

bg
TP-LINK

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
256 MHz
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Atheros
AR2414A
?x?:?, bg
Ant. conn: U.FL

Is a module
Marvell
88E6060
100M
4x LAN
Mini PCI 2007-09-07
TRENDnet TEW-635BRM V1.0R
FCC ID: S9ZTEW635BRM
wireless router

dsl modem

bgn
SerComm

CoO: Sample PRC Flag.svg
Broadcom
BCM6348S
4 MiB4,194,304 B <br />32,768 Kib <br />4,096 KiB <br />32 Mib <br />0.00391 GiB <br /> 16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br /> Broadcom
BCM4322
2x2:2, bgn
Broadcom
BCM5325E
100M
4x LAN
2008-11-24
Tecom WB1000
FCC ID: D6XWB1000
wireless router

analog phone gateway

bg
Broadcom
BCM6348S
Broadcom
BCM4318
?x?:?, bg
Ant. conn: U.FL
Broadcom
BCM5325E
100M
4x LAN
2008-05-07

See also

All SoCs have in common that they don't actually contain the DSP for the xDSL line, but
are connected to a "line driver", a separate SoC providing the physical layer adaption.
They contain an ADSL core and an ATM Core for offloading most DSL/ATM protocol overhead.

ADSL SoCs

First generation SoCs

  • BCM6335
The BCM6335 is one of the first ADSL SoCs from Broadcom and supports ADSL1.
  • BCM6345
The BCM6345 supports ADSL2 and has a PCMCIA interface, to be integrated in ADSL routers.

Second generation SoCs

  • BCM6338
An upgraded version of the BCM6335 with ADSL2+ support, USB 1.1 support as host and device.
  • BCM6348
An upgraded version of the BCM6345 with ADSL2+ support, support for a separate VoIP DSP.
It is mostly combined with the BCM6301 line driver, but can also be combined with a
BCM6505 VDSL transceiver.
  • BCM6358
It supports ADSL2+ through a BCM6301 line driver connected to the ADSL core and VDSL2
through a BCM6514 transceiver connected to the ATM core with a "utopia" connection.
It seems to integrate an VoIP DSP.

Third generation SoCs

  • BCM63281/BCM63283
Low cost ADSL2+ SoC with integrated Switch.
  • BCM6362
ADSL2+ SoC with integrated wireless and DECT.
  • BCM6368
The current generation of Broadcoms ADSL SoCs, using a new architecture through a "bonding
transceiver", supporting VDSL2/ADSL2+ and a second ADSL2+ connection simultaneusly.
  • BCM6816